Skip to content

DATEX II v3.4 Downloads

DATEX II individual modules

DATEX II data models are available as modules for engineers to select and build for their own applications.

Note

From version 16 of Enterprise Architect, the EAP file format is no longer supported, and the default file format is now QEA. In DATEX II release 3.4 both EAP and QEA formats are provided, to allow working with DATEX II models in various EA versions, though in future it is likely that only QEA files will be provided.

  • DatexIIEmptyPIM.eap - the shell of the DATEX II data model, as an Enterprise Architect .eap model. Use this as a base and then import modules or add your own extensions.
  • DatexIIEmptyPIM.qea - the shell of the DATEX II data model, as an Enterprise Architect .qea model. Use this as a base and then import modules or add your own extensions.
  • DatexIICommon.xml - the DATEX II "Common" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIILocation.xml - the DATEX II "LocationReferencing" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIEnergyInfrastructure.xml- the DATEX II "EnergyInfrastructure" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIParking.xml - the DATEX II "Parking" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIISituation.xml - the DATEX II "Situation" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIRoadTrafficData.xml - the DATEX II "RoadTrafficData" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIVms.xml - the DATEX II "VMS" namespace, as an XMI file for import to an Enterprise Architect UML model.

Note

The following two modules each contain two kinds of content:

  • Content needed for stable namespaces – this is placed in a package named “Final” and will remain backwards compatible in all version 3 releases.
  • Content needed for namespaces yet to reach their final version 3 forms – this is placed in a package named "Draft" and may change in a future version 3 release.

New content may be added to these modules in future version 3 releases

  • DatexIILocationExtension.xml - the DATEX II "CommonExtension" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIICommonExtension.xml - the DATEX II "LocationExtension" namespace, as an XMI file for import to an Enterprise Architect UML model.

Warning

Warning! The following modules are made available as drafts but have not yet reached their final version 3 forms i.e. non-interoperable changes are expected in a future v3 release.

  • DatexIIControlledZone.xml- the DATEX II "ControlledZone" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIFacilities.xml - the DATEX II "Facilities" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIGnssExtension.xml - the DATEX II "GNSSExtension" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIReroutingManagementEnhanced.xml - the DATEX II "ReroutingManagementEnhanced" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIITrafficManagementPlan.xml - the DATEX II "TrafficManagementPlan" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIITrafficRegulation.xml - the DATEX II "TrafficRegulation" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIITrafficSignals.xml - the DATEX II "TrafficSignals" namespace, as an XMI file for import to an Enterprise Architect UML model.
  • DatexIIUrbanExtensions.xml- the DATEX II "UrbanExtensions" namespace, as an XMI file for import to an Enterprise Architect UML model.

DATEX II XML Schema

DATEX II XML Schemas are provided for reference, but note that these contain the full content of their corresponding namespace. Software developers are encouraged to use the DATEX II UML models and the DATEX II schema generation tool to create profiled XML Schemas for their specific application, containing only the elements required.

DATEX II Schema generation tool

On demand a Windows version is available for expert use. Please contact helpdesk@datex2.eu

DATEX II pre-assembled models for convenience

For convenience there also pre-assembled models with common selections. These can be viewed or managed by the Enterprise Architect Tool that can be downloaded from Sparxsystems.com.

Note

From version 16 of Enterprise Architect, the EAP file format is no longer supported, and the default file format is now QEA. In DATEX II release 3.4 both EAP and QEA formats are provided, to allow working with DATEX II models in various EA versions, though in future it is likely that only QEA files will be provided.

EAP Files

QEA Files

HTML Model of DATEX II v3.4

Note

When accessed as files from the local file system, the HTML may not render correctly in all browsers - see sparxsystems.com for further details

Go back to the previous page